Product Discription
WNS Series Horizontal Biomass Gas Fired Steam Boiler
The WNS Biomass Horizontal Gas Boiler is a quick installation. A boiler with three internal combustion tubes uses a moisture compensation structure, a high-temperature combustion gas strip, and then a second three-stage fire tube. Remove from the rear exhaust box and chimney. Enter the atmosphere. The boiler is equipped with active front and rear covers of the smoke box for easy maintenance.
Product Features
1. Easy installation:
Generally, boiler boilers are quickly and easily transported and installed on site, which greatly reduces construction time, saves installation costs and can be put into operation under weather conditions.
2. Reliable operation:
The boiler has adequate heating surface, smooth water circulation and quick cooling of each heated surface, which effectively ensures safe operation of the boiler.
3. Service ability:
Boiler boilers, registered wells, can be put into maintenance. It is very convenient to open the boiler in front of the smoke box, staff can easily and clearly check the smoke box and always ensure good conditions for proper handling.
4. Fully burned:
Complete combustion of fuel and black smoke can be eliminated by secondary air and adequate furnace design.
5. Effective grid:
The ventilation grille of the double-sided boiler has a dust extraction technology, which is a natural discharge area in the front of the boiler, prevents leakage, leakage, uneven ventilation and ease of operation and has obvious advantages over a conventional grille.
6. Ashes conveniently:
A plurality of holes can be formed in the ashtray of the boiler, the ash can be effectively removed over time and unpleasant operation is prevented, since the thermal efficiency of the boiler is reduced due to ash accumulation and the boiler load is stable.
Technical Parameters
Main Technical parameters of WNS Biomass Gas-fired Steam Boiler
WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |||
Steam Capacity | t/h | 0.5 | 1 | 2 | 3 | 4 | 6 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | |
Biomass Efficiency | / | ≥88% | ||||||
Gas efficiency | / | ≥92% | ||||||
Fuel | / | Biomass particles, natural gas, liquefied gas, city gas, producer gas, light oil, etc. | ||||||
Fuel Consumption | Biomass particles | Kg/h | 89 | 177 | 355 | 532 | 711 | 1059 |
Natural gas | NM3/h | 38 | 75 | 149 | 223 | 298 | 446 | |
Liquefied gas | Kg/h | 30 | 60 | 119 | 177 | 237 | 359 | |
City gas | NM3/h | 81 | 160 | 318 | 473 | 634 | 950 | |
Producer gas | NM3/h | 258 | 517 | 1038 | 1541 | 2063 | 3111 | |
Light oil | Kg/h | 32 | 63 | 126 | 185 | 247 | 370 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | |
Running water volume | M3 | 1.2 | 1.96 | 3.4 | 4.98 | 5.63 | 7.32 |
Note: the fuel consumption in the table is low calorific value 17084KJ/Kg (4085Kcal/Kg) for biomass particles, 35588KJ/NM3 (8500Kcal/NM3) for natural gas, and 45998KJ/Kg (11000Kcal/Kg) for liquefied gas. Low calorific value of city gas 16750KJ/NM3 (4000Kcal/NM3), low calorific value of furnace gas 5650KJ/NM3 (1351Kcal/NM3), low calorific value of light oil 42915KJ/K G (10260Kcal/Kg) calculation
External and Interface Dimension of WNS Biomass Gas Steam Boiler
Shape and Interface Dimensions of WNS Biomass Gas Steam boilers | ||||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |
Transport Dimension (L*W*H) | / | mm | 3220*1550*1720 | 3730*1790*2010 | 4240*2140*2182 | 4243*2453*2488 | 4473*2470*2736 | 4530*3010*3090 |
Mainframe transport weight | / | t | 3.2 | 5.3 | 8.5 | 10.5 | 13 | 17 |
Main Steam Valve Pipe Diameter | DN | mm | 40 | 65 | 80 | 100 | 100 | 125 |
Feed Water Valve | DN | mm | 25 | 40 | 40 | 40 | 40 | 50 |
Safety Valve Diameter | DN | mm | 40 | 2*50 | 2*50 | 2*50 | 2*50 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 40 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 250 | 280 | 350 | 400 | 400 | 600 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.