Add to Cart
Product Discription
WNS Series Horizontal Biomass Gas Fired Steam Boiler
In the WNS series, the horizontal type biomass gas steam boiler is a high-speed assembly structure, an internal combustion engine, a three tubular tube boiler, and a bias type wet backrest structure is adopted, and the high temperature exhaust gas is washed out of the two or three tubes in sequence, and then discharged into the atmosphere. Boxes and chimneys. The boiler has a front and rear smoking box lid, which is convenient to repair.
Product Features
1. Convenient to clean Ashes:
A plurality of clear holes are installed in the boiler, and the ash is inspected effectively at the proper time, and the operation failure by the boiler integration and the reduction of the thermal efficiency are prevented, and the stability of the boiler load is secured.
2. High safety:
The water supply is controlled by the microcomputer and is automatically supplied. It is safe and reliable.
3. Life and durability
Boiler professional excellent design, advanced production equipment, rigorous quality inspection ensures the quality of new boilers, and the life of normal boiler bodies exceeds 20 years.
4. Environmental protection low noise
The emission of smoke from the boiler is low, and the tail has an efficient dust collector and low noise fan.
5. Manufacturing specifications:
Some of the boilers are manufactured by national standards and international standards (ISO). Each production process is strictly done by the advanced production process, ensuring that the quality of the product is reliable.
6. Services:
Technical services, instructors, periodic and indefinite return services provide excellent and perfect service for you at any time.
Technical Parameters
Main Technical parameters of WNS Biomass Gas-fired Steam Boiler
WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |||
Steam Capacity | t/h | 0.5 | 1 | 2 | 3 | 4 | 6 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | |
Biomass Efficiency | / | ≥88% | ||||||
Gas efficiency | / | ≥92% | ||||||
Fuel | / | Biomass particles, natural gas, liquefied gas, city gas, producer gas, light oil, etc. | ||||||
Fuel Consumption | Biomass particles | Kg/h | 89 | 177 | 355 | 532 | 711 | 1059 |
Natural gas | NM3/h | 38 | 75 | 149 | 223 | 298 | 446 | |
Liquefied gas | Kg/h | 30 | 60 | 119 | 177 | 237 | 359 | |
City gas | NM3/h | 81 | 160 | 318 | 473 | 634 | 950 | |
Producer gas | NM3/h | 258 | 517 | 1038 | 1541 | 2063 | 3111 | |
Light oil | Kg/h | 32 | 63 | 126 | 185 | 247 | 370 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 | 50-100 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | 70-200 | |
Running water volume | M3 | 1.2 | 1.96 | 3.4 | 4.98 | 5.63 | 7.32 |
Note: the fuel consumption in the table is low calorific value 17084KJ/Kg (4085Kcal/Kg) for biomass particles, 35588KJ/NM3 (8500Kcal/NM3) for natural gas, and 45998KJ/Kg (11000Kcal/Kg) for liquefied gas. Low calorific value of city gas 16750KJ/NM3 (4000Kcal/NM3), low calorific value of furnace gas 5650KJ/NM3 (1351Kcal/NM3), low calorific value of light oil 42915KJ/K G (10260Kcal/Kg) calculation
External and Interface Dimension of WNS Biomass Gas Steam Boiler
Shape and Interface Dimensions of WNS Biomass Gas Steam boilers | ||||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | |
Transport Dimension (L*W*H) | / | mm | 3220*1550*1720 | 3730*1790*2010 | 4240*2140*2182 | 4243*2453*2488 | 4473*2470*2736 | 4530*3010*3090 |
Mainframe transport weight | / | t | 3.2 | 5.3 | 8.5 | 10.5 | 13 | 17 |
Main Steam Valve Pipe Diameter | DN | mm | 40 | 65 | 80 | 100 | 100 | 125 |
Feed Water Valve | DN | mm | 25 | 40 | 40 | 40 | 40 | 50 |
Safety Valve Diameter | DN | mm | 40 | 2*50 | 2*50 | 2*50 | 2*50 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 40 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 250 | 280 | 350 | 400 | 400 | 600 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.