Add to Cart
Product Discription
The boilers of the YY (Q) W series, also known as organic boilers for heat transport, use oil and gas as fuel, heat oil As a medium, through the Heat circulating oil pump Medium liquid cycle, transfer thermal energy t o the USO of equipment t Heat, returned to the oven for heating, and then heated by the heating oven, The heat obtained Can satisfy the requirements of the boiler. The performance of the acquisition at low temperature is characterized by the acquisition at low temperature. Its heating temperature can reach 320 in liquid phase or 400 in steam phase. Heat oil boilers can be used for heating on any production line that requires uniform and stable heating, which does not allow direct heating of the Flame, and whose temperature V It would go from 250 to 380 degrees Celsius.
The heating surface of the Caldeira is compact in the structure. The heating surface is composed of internal, medium, external (or internal, external) circular coils arranged on nearby lines. The internal coils absorb most of the heat from the heating surface of the radiation, and the high temperature flow gas enters the convective heating surface. Transfer heating Nd. The combustion gas from the Caldeira output is absorbed by the heat exchanger Na End of the pot and discharged into the atmosphere through the chimney.
Product Features
1. Easy to install:
Boilers are generally divided into upper and lower parts that are convenient for transport and installation on site, significantly shortens the installation cycle, saves installation costs, and allows the boiler to be started on time.
2. Reliable action:
The heating surface of the boiler is reasonably positioned and the hot oil circulation is smooth, which ensures the timely cooling of the kilns and the safe operation of the boiler.
3. Simple maintenance:
The boiler is equipped with several controls, the maintenance staff control is convenient and clear, giving good conditions for proper work.
4. Complete combustion:
The boiler piston is high, the fuel can be completely burned, in cooperation with secondary air, can effectively remove black smoke.
5. High efficiency grate:
The boiler grate uses two -way ventilation, which brings the ash grate forward and releases it. It avoids air leakage, oil leakage and uneven ventilation, is easy to use and has many advantages over the traditional grid.
6. Ash is easy to remove:
Installation of a heat blower in the boiler's convex heat transmission zone may remove soot quickly and effectively, avoid the effects of soot accumulation on the boiler's work or reduce thermal energy and ensure stability of the boiler's load. The heat blower shall be so equipped that it does not affect the accumulation of soot in the boiler.
Technical Parameters
Main Technical parameters of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler | ||||||||
Item | Unit | YY(Q)W -1400Y(Q) | YY(Q)W -2100Y(Q) | YY(Q)W -3000Y(Q) | YY(Q)W -4200Y(Q) | YY(Q)W -6000Y(Q) | YY(Q)W -7000Y(Q) | |
Thermal Power | KW | 1400 | 2100 | 3000 | 4200 | 6000 | 7000 | |
Heat Supply | 104Kcal/h | 120 | 180 | 250 | 360 | 500 | 600 | |
Working Pressure | MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |
Rated oil output temperature | ℃ | 300 | 300 | 300 | 300 | 300 | 320 | |
Rated oil return temperature | ℃ | 280 | 280 | 280 | 280 | 280 | 300 | |
Thermal Efficiency | / | ≥92% | ||||||
Fuel | / | Natural gas, liquefied gas, city gas, light oil | ||||||
Fuel Consumption | Natural gas | NM3/h | 163 | 243 | 349 | 489 | 692 | 809 |
Liquefied gas | Kg/h | 127.7 | 189.9 | 269 | 376.8 | 535.7 | 624.8 | |
City gas | NM3/h | 347.9 | 518.7 | 738.3 | 1036 | 1465.4 | 1706 | |
Light oil | Kg/h | 139.3 | 203 | 287.3 | 415.2 | 571 | 665 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 100-200 | 100-200 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 100-200 | 100-200 | |
Rated circulating oil quantity | M3/h | 82.95 | 125.5 | 177.7 | 248.8 | 355 | 413 | |
Mainframe Oil Volume | M3 | 1.19 | 1.6 | 2.2 | 3.92 | 4.3 | 5.9 |
Note: the fuel consumption in the table is based on light oil low calorific value 42915KJ/Kg (10260Kcal/Kg), natural gas low calorific value 35588KJ/NM3 (8500Kcal/NM3) and liquefied gas low calorific value 45998KJ/Kg (11000Kcal/Kg). Calculation of low calorific value (16750KJ/NM3 (4000Kcal/NM3) of urban gas.
Shape and Interface Dimensions of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler | ||||||
Item | Unit | YY(Q)W -1400Y(Q) | YY(Q)W -2100Y(Q) | YY(Q)W -3000Y(Q) | YY(Q)W -4200Y(Q) | |
Transport Dimension (L*W*H) | / | mm | 4424*1950*2243 | 5170*2250*2460 | 5808*2505*2820 | 7082*2970*3140 |
Mainframe transport weight | / | t | 6.2 | 8.7 | 11 | 18 |
Outlet Diameter | DN | mm | 125 | 125 | 150 | 200 |
Return Pipe Diameter | DN | mm | 125 | 125 | 150 | 200 |
Drain Valve Pipe Diameter | DN | mm | 25 | / | / | / |
Discharge Pipe Diameter | DN | mm | 25 | 40 | 40 | 40 |
Chimney Diameter | φ | mm | 350 | 400 | 500 | 600 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.