Add to Cart
Product Discription
YY (q) w -boiler, whether or not known as an organic heat boiler, uses oil and gas as fuel, hot oil as medium, medium fluid circulation, transfers heat energy to the use of thermal equipment, returns to R -heaters and is then heated by heaters, and the heat obtained can meet the requirements of the boiler.Purchase at low temperatures is characterised by low temperatures.The temperature at liquid heating can reach 320 and the steam heat can reach 400.The heat surface consists of inner, middle and outer (or inner and outer) circular rings with narrow arrangement.The internal coil absorbs most of the heat from the heat surface of the radiation, and the flue -gas at high temperature enters the convective heat surface.Heat for transmission.The flue -gas in the forehead i s absorbed by the heat exchanger at the end of the forehead and released into the atmosphere through the chimney.
Product Features
1. High security:
It is controlled by a computer and is equipped with a heat shield, an overheating device and a high voltage device, which is safe and reliable.
2. Long life and sustainability:
An excellent professional design, advanced production technology, strict quality control and quality control are the quality assurance of each boiler, and the normal life of the boiler is more than twenty years.
3. Environmental protection and low noise:
Smoke gas emissions from coking plants are low, with recycling of waste heat, high -efficiency dust collectors, low -noise fan, so that the flue -gas emissions meet national environmental protection requirements.
4. Production standards:
Cocaine components are manufactured in accordance with national and international standards (ISO). All processes strictly follow advanced production technology to ensure product quality.
5. Good service:
Technical consultation, technical services, installation management, regular and irregular care services for users, at any time to provide quality and perfect services to ensure that our customers buy and use them safely.
Technical Parameters
Main Technical parameters of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler | ||||||||
Item | Unit | YY(Q)W -1400Y(Q) | YY(Q)W -2100Y(Q) | YY(Q)W -3000Y(Q) | YY(Q)W -4200Y(Q) | YY(Q)W -6000Y(Q) | YY(Q)W -7000Y(Q) | |
Thermal Power | KW | 1400 | 2100 | 3000 | 4200 | 6000 | 7000 | |
Heat Supply | 104Kcal/h | 120 | 180 | 250 | 360 | 500 | 600 | |
Working Pressure | MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |
Rated oil output temperature | ℃ | 300 | 300 | 300 | 300 | 300 | 320 | |
Rated oil return temperature | ℃ | 280 | 280 | 280 | 280 | 280 | 300 | |
Thermal Efficiency | / | ≥92% | ||||||
Fuel | / | Natural gas, liquefied gas, city gas, light oil | ||||||
Fuel Consumption | Natural gas | NM3/h | 163 | 243 | 349 | 489 | 692 | 809 |
Liquefied gas | Kg/h | 127.7 | 189.9 | 269 | 376.8 | 535.7 | 624.8 | |
City gas | NM3/h | 347.9 | 518.7 | 738.3 | 1036 | 1465.4 | 1706 | |
Light oil | Kg/h | 139.3 | 203 | 287.3 | 415.2 | 571 | 665 | |
Gas Feed pressure | Natural Gas | mbar | 50-100 | 50-100 | 50-100 | 50-100 | 100-200 | 100-200 |
City Gas | mbar | 70-200 | 70-200 | 70-200 | 70-200 | 100-200 | 100-200 | |
Rated circulating oil quantity | M3/h | 82.95 | 125.5 | 177.7 | 248.8 | 355 | 413 | |
Mainframe Oil Volume | M3 | 1.19 | 1.6 | 2.2 | 3.92 | 4.3 | 5.9 |
Note: the fuel consumption in the table is based on light oil low calorific value 42915KJ/Kg (10260Kcal/Kg), natural gas low calorific value 35588KJ/NM3 (8500Kcal/NM3) and liquefied gas low calorific value 45998KJ/Kg (11000Kcal/Kg). Calculation of low calorific value (16750KJ/NM3 (4000Kcal/NM3) of urban gas.
Shape and Interface Dimensions of YY(Q)W Series Horizontal Oil & Gas Fired Thermal Oil Boiler | ||||||||
Item | Unit | YY(Q)W -1400Y(Q) | YY(Q)W -2100Y(Q) | YY(Q)W -3000Y(Q) | YY(Q)W -4200Y(Q) | YY(Q)W -6000Y(Q) | YY(Q)W -7000Y(Q) | |
Transport Dimension (L*W*H) | / | mm | 4424*1950*2243 | 5170*2250*2460 | 5808*2505*2820 | 7082*2970*3140 | 8100*3190*3430 | 8910*3370*3620 |
Mainframe transport weight | / | t | 6.2 | 8.7 | 11 | 18 | 26 | 30 |
Outlet Diameter | DN | mm | 125 | 125 | 150 | 200 | 200 | 250 |
Return Pipe Diameter | DN | mm | 125 | 125 | 150 | 200 | 200 | 250 |
Drain Valve Pipe Diameter | DN | mm | 25 | / | / | / | / | / |
Discharge Pipe Diameter | DN | mm | 25 | 40 | 40 | 40 | 40 | 50 |
Chimney Diameter | φ | mm | 350 | 400 | 500 | 600 | 700 | 800 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.