Add to Cart
Product Discription
LSS oil and gas fired vertical steam generator
LSS fuel gas vertical vapour generator receives the structure of the vertical plumbing.There are two tubes between the tops and bottom sheets of the main body and one casing welded together with three cycles of flue gas. area and reasonable structural arrangement.The combustion is fixed at the top of the body and the light can completely expand and burn.
With the boiler and condenser the thermal efficiency can reach 93%100%%.The built -in steam separator and the external steam separator provide high -quality dry steam, save fuel, reduce system expansion and extend service life.
1. High safety:
no need for inspection, steam generator water volume less than 30Kg, high safety. No installation notice is required.
2. Easy Maintenance:
Inspection doors are set at the bottom to check and clean the furnace interior for easy maintenance.
3. in line with environmental protection:
high quality and reliable burner, so that fuel can be fully burned, while greatly reducing harmful emissions in flue gas. The test results of relevant departments show that the fuel (gas) steam generator meets the national environmental protection requirements.
4.The amount of evaporation can be increased:
Steam generators can be modularized into several units (unlimited number) and controlled by computer.Total evaporation can be added freely.The relevant components of steam generator (including water treatment, water pump, burner, electronic control box and main valve instruments) are already in the factory.
5. Installation is an integral whole:
It can be connected with water, electricity and steam pipes on site, which saves time and effort in installation.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.