Add to Cart
Product Discription
LSS oil and gas fired vertical steam generator
The vertical steam generator LSS fuel gas has a vertical pipe structure. There are two rings made of pipe bundles and a pipe welded between the upper and lower tube blades of the main body to form a three -cycle exhaust. The exhaust gas has a long heat transfer process ss, a large heating area and a reasonable structure. The burner is set on the top of the body, and the flame can fully expand and burn.
The thermal efficiency 93% 100% can be achieved with boiler and condenser. Built -in steam water separators and external steam water separators provide a high quality dry steam, save fuel, reduce the scaling of the plant and extend the service life.
1. in line with environmental protection:
high quality and reliable burner, so that fuel can be fully burned, while greatly reducing harmful emissions in flue gas. The test results of relevant departments show that the fuel (gas) steam generator meets the national environmental protection requirements.
2. The amount of evaporation can be increased:
Steam generators can be modularized into several units (unlimited number) and controlled by computer.Total evaporation can be added freely.The relevant components of steam generator (including water treatment, water pump, burner, electronic control box and main valve instruments) are already in the factory.
3. Installation is an integral whole:
It can be connected with water, electricity and steam pipes on site, which saves time and effort in installation.
4. Reliable accessories:
matching burners, control boxes, water treatment, and valves, pumps are made of domestic high-quality equipment. The matching equipment can ensure the safe and reliable operation of the steam generator and improve the overall quality of the steam generator.
5. excellent control system:
the boiler is equipped with perfect automatic control device and safety protection device to realize automatic water level control System and low water level alarm, stoppage; steam pressure automatic control and overpressure alarm; boiler automatic ignition, burner self-fire Dynamic regulation and flameout protection ensure the safe operation of the boiler. Users only need to press the start button lightly, the steam generator can press it.
6. Quality Services:
Technical Consulting, Technical Services, Installation Guidance, Regular and Irregular Visits to Users,Provide high-quality and perfect services at any time, so that users can buy at ease, with comfort
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | t | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.