Add to Cart
WNS Series 2 Tons Oil Diesel Fired industrial Steam Boiler
Brief Introduction of Boiler Operating Conditions
The engine can be operated under 80% in 100% operating mode. Under 100 barrels, refrigeration systems include: 20 ° C water heater, 1.25 MPa working pressure, 10 pounds can be produced in an hour, and the heat is 193.4 ° C. The average body temperature was 98.96, the average body temperature was 48.93 ° C, and the use of the tea was 754.78 Nm3 / h (dose used once a day ). The natural gas content is very low (> 36.36 MJ / NM3).
Product Features
1. Reasonable design
2. High efficiency and energy saving
3. Manufacturing specifications
4. Large steam space
Technical Parameters
Main Technical parameters of WNS Series Steam Boiler | |||||||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | WNS4 | WNS6 | WNS10 | WNS15 | WNS20 | |
Steam Capacity | t/h | 0.5 | 1 | 2 | 3 | 4 | 6 | 10 | 15 | 20 | |
Working Pressure | MPa | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Steam Temperature | ℃ | 184 | 193 | 193 | 193 | 193 | 193 | 193 | 193 | 193 | |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 104 | 104 | 104 | |
Thermal Efficiency | / | ≥96% | |||||||||
Fuel | / | Natural gas, liquefied gas, city gas, light oil | |||||||||
Fuel Consumption | Natural gas | NM3/h | 37 | 73 | 145 | 217 | 289 | 435 | 735 | 1101 | 1467 |
Liquefied gas | Kg/h | 30 | 58 | 117 | 174.5 | 232 | 351 | 589 | 871 | 1151 | |
City gas | NM3/h | 79 | 157 | 309 | 462 | 615 | 943 | 1575 | 2357 | 3147 | |
Light oil | Kg/h | 32 | 61 | 121 | 182 | 243 | 367 | 601 | 906 | 1211 | |
Gas Feed pressure | Natural Gas | mbar | 70-100 | 100-150 | 100-150 | 150-200 | 150-200 | 150-200 | 150-200 | 150-300 | 150-300 |
City Gas | mbar | 100-200 | 100-200 | 100-200 | 150-200 | 150-200 | 150-200 | 150-200 | 150-300 | 150-300 | |
Running water volume | M3 | 0.78 | 3.3 | 3.6 | 5.2 | 6 | 9 | 11.6 | 24.5 | 29 |
Note: the fuel consumption in the table is based on light oil low calorific value 42915KJ/Kg (10260Kcal/Kg), natural gas low calorific value 35588KJ/NM3 (8500Kcal/NM3) and liquefied gas low calorific value 45998KJ/Kg (11000Kcal/Kg). Calculation of low calorific value (16750KJ/NM3 (4000Kcal/NM3) of urban gas.
Shape and Interface Dimensions of WNS Biomass Steam boilers | ||||||
Item | Unit | WNS0.5 | WNS1 | WNS2 | WNS3 | |
Transport Dimension (L*W*H) | / | mm | 2949*1454*1707 | 3198*1880*2166 | 4131*2247*2422 | 4485*2010*2402 |
Mainframe transport weight | / | t | 2.8 | 4.9 | 8 | 9 |
Main Steam Valve Pipe Diameter | DN | mm | 40 | 65 | 80 | 100 |
Feed Water Valve | DN | mm | 25 | 40 | 40 | 40 |
Safety Valve Diameter | DN | mm | 40 | 2*40 | 2*40 | 2*50 |
Drain Valve Pipe Diameter | DN | mm | 40 | 40 | 2*40 | 2*40 |
Chimney Diameter | φ | mm | 250 | 280 | 300 | 400 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.