Add to Cart
Product Discription
LSS Oil Fired Steam Generator
LSS oil and gas fired vertical steam generator adopt vertical tubular structure. There are two circles of pipe bundles and a shell cylinder welded between the upper and lower tube sheets of the body to form a three-return flue gas. It has a long flue gas heat transfer process, sufficient heating area and reasonable structure layout. The burner is arranged on the top of the body, and the flame can be fully expanded and fully burned.
1. Reasonable design: The steam generator body adopts vertical tubular structure, and the upper and lower Tube sheets of the body are welded with two coils of water pipe bundles.The utility model and a shell cylinder form a flue gas three-return journey together. With long flue gas heat transfer process, sufficient heating area and reasonable Structural layout. The burner is arranged on the top of the body, and the flame can be fully expanded and fully burned.
2. High efficiency and energy saving: the thermal efficiency of steam generator can reach more than 92%, and the efficiency of steam generator can reach more than 96% if it is equipped with condenser.
3. Manufacturing Specification: Each component of steam generator is manufactured in accordance with national and international standards (ISO).All production links strictly follow strict production process to ensure reliable product quality.
4. Steam drying: Steam generator has built-in steam-water separator, which can provide high quality drying steam. Because of dry steaming. Steam helps eliminate unnecessary extra condensation, thereby saving fuel, reducing system scaling and prolonging service life.
5. Reliable and durable: Excellent professional design of steam generator, excellent production process, strict quality control, is every one.Quality assurance of steam generator in Yuji.
Technical Parameters
Main Technical Reference for Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSS0.1 | LSS0.15 | LSS0J2 | ||
Rated evaporation | Kg/h | 50 | 100 | 150 | 200 | |
Rated Pressure PTEPREppoPressure | MPa | 0.4/0.7 | ||||
Rated steam temperature | c | 151/171 | ||||
Rated feed water temperature | °C | 20 | ||||
Evaporator efficiency | / | >92% | ||||
Applicable Fuel | / | Gas light oil | ||||
Theoretical fuel consumption | Gas | NM3/h | 4 | 8 | 12 | 16 |
Light Oil | Kg/h | 3.3 | 6.5 | 9.8 | 13 | |
Gas supply pressure | mbar | 60- 100 | ||||
water volume | L | <30 |
Note: The fuel consumption in the table is based on the low calorific value of biomass particles 17084 KJ/Kg (4085 Kcal/Kg).Calculations show that if the low calorific value of biomass fuel is higher than that, the corresponding fuel consumption will be more economical than the values in the table.
Configuration and Interface Size of Fuel (Gas) Steam Generator | ||||||
Item Unit | LSS0.05 | LSSO.l | LSS0.15 | LSS0.2 | ||
Outward Size of Main Engine
(length * width * height) | / | mm | 620*620*830 | 690*690*968 | 750*750*1130 | 800*800*1286 |
Transport Dimension
| / | mm | 206 | 252 | 303 | 350 |
Mainframe Transport Weight | DN | mm | G 1/2- | Gl' | Gl" | G 1* |
Main Steam Valve Pipe Diameter | DN | mm | Gl/2" | Gl/2- | Gl/2- | Gl/2° |
Feed Water Valve | DN | mm | G1 1/4” | G11/4- | G11/4- | G11/4- |
Safety Valve Diameter | DN | mm | Gf | GF | Gl" | Gl" |
Drain Valve Pipe Diameter | DN | mm | 133 | 133 | 159 | 159 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.